Refurbished Fetal Monitor Corometrics® 118 Series 0 to 100 mmHg Range Pressure, 1 mmHg Resolution; Peak Detecting Beat-to-Beat Cardio Tachometer, 30 to 240 bpm Heart Rate; Pulsed Doppler with Autocorrelation Processing, 100 W Power Consumption

$3,728.89
MONITOR, FETAL HEART COROMETRICS 118
SKU
1011066624
Non-stock item.

Product Specifications

SLI Medical#1066624
Manufacturer #GEN-053
BrandCorometrics® 118 Series
ManufacturerSoma Technology
Country of OriginUnited States
ApplicationRefurbished Fetal Monitor
Dimensions7 X 16.5 X 17 Inch
Display TypeDigital Display
Power SourceAC Power
Specifications0 to 100 mmHg Range Pressure
Test Name 1 mmHg Resolution; Peak Detecting Beat-to-Beat Cardio Tachometer
UNSPSC Code 30 to 240 bpm Heart Rate; Pulsed Doppler with Autocorrelation Processing
Weight 100 W Power Consumption
Fetal Heart Rate
42143120
34 lbs.

Features

  • Refurbished in an ISO 13485 Certified FDA registered Facility Toco
  • ultrasound transducer and ECG Provides simultaneous
  • noninvasive monitoring of twins as well as internal/external monitoring and maternal ECG Data storage and transmission Integrated maternal pulse oximetry and NIBP monitoring Pulse repetition frequency: 4 kHz in single ultrasound mode
  • 2 kHz in dual ultrasound mode 92 µs Pulse duration
  • 1.151 MHz center frequency
  • <10 m w/cm2 Intensity
  • 50-210 BPM Heart rate counting range
  • < 10 µA at 120 VAC leakage current Bandwidth Tocotransducer DC to 0.5 Hz
  • strain gauge DC to 3 Hz Zero temperature drift < 0.1 mmHg/°C (electronics only) <10 µA at 120 VAC (transducer isolated) leakage current ±1 bpm Heart rate resolution Switch selectable±25 BPM artifact rejection artifact elimination 15 µV to 2 mV peak-to-peak (fetal)
  • 100 µV to 2 mV peak-to-peak (maternal) Input signal range differential 20 VDC (max.) Common mode 1 to 100 Hz Preamplifier bandwidth Common mode rejection >120 dB balance
  • with patient cable >110 dB 5k RA or LA unbalance < 10 µV peak-to-peak Input equivalent noise Differential mode > 10 MΩ
  • common mode > 20 MΩ Input impendence >40 Db Main frequency rejection
MONITOR, FETAL HEART COROMETRICS 118
Additional Information
Product NameRefurbished Fetal Monitor Corometrics® 118 Series 0 to 100 mmHg Range Pressure, 1 mmHg Resolution; Peak Detecting Beat-to-Beat Cardio Tachometer, 30 to 240 bpm Heart Rate; Pulsed Doppler with Autocorrelation Processing, 100 W Power Consumption
SKU1011066624
Price$3,728.89
Weight5.25
Featured ProductNo
Manufacturer SkuGEN-053
UOMEA
ManufacturerCorometrics® 118 Series
Short DescriptionMONITOR, FETAL HEART COROMETRICS 118